Hall Missing Error protection disabling in case of the linear Hall sensors

Author: AM Reference Number: AA-00385 Views: 3219 Created: 18-05-2012 12:30 Last Updated: 06-05-2021 14:28 0 Rating/ Voters

In case of the linear Hall sensors, the "Hall missing" error is caused by the differences between the Hall sensors amplitude and/or their shape.
This can be verified using the the Logger, in EasyMotion Studio or Easy SetUp, that will be set to show the "AD3" (LH1 - 1st linear Hall sensor value), "AD6" (LH2 - 2nd linear Hall sensor value) and "AD9" (LH3 - 3rd linear Hall 3 value) variables.

If the case, the "Hall Missing" protection can be disabled by setting the ALPHA parameter to 0.
The ALPHA parameter can be founded in the "parameters.cfg" file, from the project folder. The default the path to this file is: C:\Program Files (x86)\Technosoft\ESM\Projects\Project_Name\Application_Name.